AP postoperative X-ray image demonstrating dorsal and circumferential plating of the multifragmentary patella fracture. 0000036569 00000 n Contact Us 0 Single-use instruments surgical protocol (48 pages) Medical Equipment Stryker Prime TC 1450 Operation & Maintenance Manual. Resource Type: Surgical Technique Videos Presenter: Todd M. Oliver, MD Revision Date: Total Joint Arthroplasty in Younger Patients: Heading for Trouble? Bhowmik-Stoker et al. Accepted manuscript. Social Responsibility, Copyright 2022 Acumed LLC, a Colson Medical | Marmon | Berkshire Hathaway company, Locking Scapula Plate System Brochure & Surgical Technique, Profile Zero Low Profile Neuro Plating System, Profile Plus Standard Profile Plating System, Acutrak 2 Headless Compression Screw System, ExtremiFix Cannulated Screw System | Mini & Small, ExtremiFix Cannulated Screw System | Midsize & Large. Asnis Micro Xpress. Large bone fragments compression bone plate AxSOS Stryker Cystoscope endoscope / rigid Stryker Human intramedullary nail / humerus Gamma3 Stryker Patented SmartLock polyaxial locking technology, Locking screws can be angled 15 for a total range of 30. The Journal of Arthroplasty 32 (2017) 2151-2155. 18 43 The set includes everything needed to perform a traditional repair. Note the extensive multifragmentary fracture pattern on the AP. Foot & Ankle Videos The largest fragments are reduced and temporary fixed with K-wires. The resulting construct should be strong enough for early motion to be started. AdvaMed Code of Ethics Hip & Pelvis Certain products may not be approved for sale in all countries. Patellar plating for Complete articular, frontal/coronal Instrument Bar 6541-3-602 Patella Caliper 6541-3-702 Small Patella Clamp Jaw Right 6541-3-703 . 0000032321 00000 n This video demonstrates a medial column fusion. Stryker Knee Replacement Components - Brandon Orthopedics The precontoured plates minimize the need for bending while acting as a template for optimal implant placement and guiding screw fixation to osseous regions. Current Problems in Diagnostic Radiology, July/August 2010. Durepair is a registered trademark of TEI Biosciences Inc.DuraGen is a registered trademark of Integra Lifesciences CorporationDuraMatrix-Onlay PLUS and DuraMatrix Suturable are trademarks of Collagen Matrix, Inc.DuraMatrix-Onlay and DuraMatrix are registered trademarks of Collagen Matrix, Inc.DuraMatrix-Onlay PLUS, DuraMatrix Suturable, DuraMatrix-Onlay and DuraMatrix are manufactured by Collagen Matrix, Inc., Oakland, New Jersey USA. Triathlon Tritanium Knee System. Simple Fractures - Core, 3-hole, and 6-hole plates may be used, based on fracture complexity. 0000015320 00000 n Accepted manuscript. Organize in-house training events for your surgical staff, Hand Distal phalanges revision published. The Patella Fracture System includes everything needed to repair transverse patella fractures. News The adaptability design allows for modularity and variable angles, you can base screw positoning on your patient at hand, not a plate's pre-existing design. Universal mesh - Stryker CMF Plating that fits. The reduction of this fracture requires careful planning. A Review of factors that affect artifact from metallic hardware on multi-row detector computed tomography. The plates can be used circumferentially around the patella, in a similar fashion to a cerclage wire, or across the surface to resist distraction forces. Miller et al. J Arthroplasty. In frontal/coronal (transverse) fractures, reduction is easier with the knee extended. Patella fractures represent approximately 1% of all fractures and present in a variety of patterns, which can make osteosynthesis challenging. VariAx 2 | Stryker Designed for direct medial or posteromedial placement You can use it in conjunction with proximal lateral tibia plate May allow for a less rigid construct, potentially resulting in increased callus formation and secondary healing1 Provides increased CT imaging clarity2 Offers excellent biocompatibility3,4 AxSOS 3 Ti Proximal Lateral Tibia The Patella Fracture System includes everything needed to repair transverse patella fractures. Full weight bearing may be performed with a straight knee, using crutches or a walker, from postoperative day 1. All other trademarks are trademarks of their respective owners or holders. A surgeon must always rely on his or her own professional clinical judgment when deciding whether to use a particular product when treating a particular patient. Functional outcomes of revision osteosynthesis after failure of surgical treatment of patellar fractures. The Acumed Medial Border Plate offers an effective plating system for stabilizing fractures of the scapula body. Simplicity and adaptability with seven new indication specific plates using the comprehensive locking and non-locking screw system. Patella Fracture Fixation Using Cannulated Screws with - Arthrex Simple Fractures - Core, 3-hole, and 6-hole plates may be used, based on fracture complexity. Patello-femoral prosthesis AVON Stryker - HealthManagement.org Further customization through contouring of the plate onto the bone may be performed before placing the screws. The implant is held . Follow Stryker's Trauma team on Social Media! Published online May 29, 2020. TheDall-MilesTrochantericGripPlatecanbeaugmentedwithStrykerSPScorti-cal bonescrewstoprovideadditionalrotational stability.Arangeof4.5mmscrewscommencingwith14mmlengthareavailableinbothTitaniumandStainlessSteel. Why cementless TKA? Pilon fractures are defined as intra-articular fractures of the distal tibial plafond and being in a load bearing joint they are serious and usually life changing . Tibia and femur | Stryker Information for Tibia and femur Our portfolio of lower extremities products includes a comprehensive array of intramedullary nails, locking plates, external fixation, and biologics. PROstep MIS | Stryker It is, therefore, highly desirable, in patellar fractures to strive for anatomical reduction of the joint surface and stable fixation. Trends in demographics, comorbidity profiles, in-hospital complications and mortality associated with primary knee arthroplasty. A specific type of failure of a metal-backed patella occurred, consisting of a separation of the polyethylene from the metal backing. 16th Annual Report. endobj Yayac et al. The progressive increase in loading of the patello-femoral joint depends on many factors and requires planned individual programs, designed by the surgeon and physical therapists. 2018;33(4):1089-1093. 2017;32(7):2156-2160. Surgical management of osteoarthritis of the knee. This video depicts a correction of a hallux valgus deformity using a lapidus procedure, a fusion of the first metatarsal with the medial cuneiform. For further information please read our cookie policy. 0000034919 00000 n Agility Total Ankle Titanium alloy tibial Cementless total knee arthroplasty (TKA) with Triathlon Tritanium is the latest evolution in the Triathlon knee portfolio. 0000016739 00000 n The surgical technique guide includes two sections: Complex Fractures - 3-hole and 6-hole plates are recommended. In addition, FiberTape suture has been attached to 5 in needles designed to pass through the screws, subsequently allowing for its use as a tension band. Journal of Knee Surgery. Tradeshows, About On the mechanisms of biocompatibility. Our plating portfolio ranges from indication specific plates and patented Smartlock technology to streamlined instrumentation for ease-of-use in the OR. Hoffmann II Compact External Fixation System For Use in Maxillofacial Surgery. The Acumed Glenoid Plate provides an effective plating solution for fractures of the posterior margin of the glenoid and displaced intra-articular glenoid fractures. For this procedure a mid-axial longitudinal approach is used. Triathlon Tritanium combines the kinematics of Triathlon with the latest in highly porous biologic fixation technology. Elbow Utilization rates of knee-arthroplasty in OECD countries. 0000002679 00000 n Contact Info The Acumed Scapula Plating System offers indication-specific titanium plates that can address challenging fractures of the scapula, including the glenoid, medial and lateral border, acromion, and scapular spine. Despite, wearing a splint to protect against never losing complete extension, range of motion is done throughout the day with the splint off. Bhowmik-Stoker et al. STRYKER TRIATHLON TRITANIUM SURGICAL MANUALLINE Pdf Download Non-locking 2.4 and 2.7 plates are typically used for the patella. The same patient with the lateral image demonstrating multiple plates and the best possible articular reconstruction for this multifragmentary fracture. 5256. 0000044584 00000 n Medial column arthrodesis with VariAx plate. Outcomes of newer generation cementless total knee arthroplasty: beaded periapatite-coated vs highly porous titanium-coated implants. Calcaneo cuboid arthrodesis with VariAx plate. Arthrex - Patella Fracture System American Academy of Orthopaedic Surgeons (AAOS). Adherus AutoSpray and Adherus AutoSpray ET. 0000017511 00000 n Active knee function requires an intact knee extensor mechanism, a mobile patella, a well-preserved patello-femoral joint and muscle strength.After satisfactory reduction and fixation of patellar fractures, early controlled range of motion exercises are combined with static quadriceps strengthening exercises. Recon nailing system r2.0 (44 pages) Medical Equipment Stryker Triathlon Surgical Manualline. 0000049387 00000 n 2017. Images The precontoured plates minimize the need for bending while acting as a template for optimal implant placement and guiding screw . 3: Conditional 6 More. It covers the incision, the desired outcome, the osteotomy and fixation. PROSTEP MIS utilizes percutaneous, micro incisions to correct bunions as well as perform DMMO, cheilectomy and other procedures. hb```b`` vAX,3Mp X':Z$PY"}n5. If you choose to logout it will log you out from all the applications. The Patella Fracture Set was specifically designed to address common obstacles (eg, amount of comminution, degree of osteoporosis, and natural forces across the patella) and to facilitate fixation of challenging injuries. Adherus and Adherus ET are the only FDA-approved hydrogel dural sealant with a patent pendingAutoSpray applicator with internal air pump. National Joint Registry for England, Wales and Northern Ireland and Isle of Man. TI4580 Mesh Upgrade 3D Mesh Impression Test with 70mm Defect. Triathlon Tritanium Knee System Knee Design Triathlon & The Single Radius Stable primary fixation of the implant is a prerequisite for biologic fixation.8 The less constrained the design, the less potential for stresses generated at the articulating surface to be transferred to the bone-implant interface.10 Triathlon CR and PS systems are designed to minimize dynamic stress transfer to the . 0000024869 00000 n This set includes 4.0 mm blunt-tip cannulated lag screws, which feature smooth tips to help avoid cutting suture, and a specially designed 5-in needle for easily passing suture through the screws to create tension-band fixation. Report A Complaint Patellar stability and osteosynthesis rates have been shown to improve significantly with locked plates.2 Arthrex mesh plates can be used in conjunction with this set for fixation of these frequently challenging injuries. Lapidus procedure for hallux valgus correction. Clinical Orthopaedics and Related Research (2011) 469:1757-1765. Send us a message to learn more about AxSOS 3 Ti Proximal Tibia and its capabilities. J Arthroplasty. Injury 31 (2000) S-D7-13. T: 888.627.9957 2 Pages. TI4579 Mesh Upgrade 3D Mesh Impression Test with Maximum Defect. Countersink - designed to reduce palpability, MR conditional - allows diagnosticsafter implantation, Variety of mesh types - strength vs malleability, New 0.3mm Hybrid mesh - 3x stronger than 0.3mm Dynamicmesh1, Has stiffness equivalent to golden 2D mesh2, Used for open defects up to 70mm and muscle attachment3, Pre-formed minimizes bending effort to fitpatient, MR conditional allows diagnostics after implantation, Countersink - designed to reducepalpability, Increased stiffness, for increased patientprotection, compared to 2D mesh2, Used for open defects up to the size of the mesh and muscle attachment3, Anatomically pre-formed minimizes bending to fit patient, MR conditional allows diagnostics afterimplantation, 1. X-rays should be taken at 2, 6 and 12 weeks. Stryker's Tritanium 3D porous metal technology is found on the metal underside of the patella, as demonstrated by the Tritanium Metal-Backed Patella*. All Stryker catalogs and technical brochures - MedicalExpo Screw & Pin The demonstration is performed by Dr. Kai Olms. Documents The Acromion Plates are an integral piece of the Scapula Plating System, and may be used individually or together with the Acumed Medial Border Plate, Lateral Border Plate, and Glenoid Plate. Solving complicated fractures with simple innovative solutions Plating that fits. The locking patella plate (Arthrex, Munich, Germany) is available in two different specifications: the Arrowplate and the Starplate ( Fig. J Knee Surg. Care should be taken to prevent screw penetration into the joint. Privacy Policy Grants Dr. Adam Schiff demonstrates a Fifth Metatarsal procedure using VariAx fracture plates. Orthopedics. <]/Prev 484465>> Todd M. Oliver, MD, (Columbia, MO) demonstrates patella fracture fixation using 4.0 mm blunt tipped cannulated screws along with a FiberTape tension band. The 4.0 mm blunt-tipped cannulated screws were designed specifically for patella fractures. 0000031476 00000 n Locking plate system for reconstruction or arthrodesis of small bones, including the fore, mid- and hind foot and ankle. All other trademarks are trademarks of their respective owners or holders. An effective plating solution for fractures of the posterior margin of the glenoid and displaced intra-articular glenoid fractures. Harwin et al. #2263, A prospective, randomized controlled study of 76 Triathlon Tritanium Baseplates with CR PA beaded femurs vs. 65 Triathlon CR cemented TKAs demonstrated excellent clinical results with no aseptic loosening in either cohort at two-year follow-up.8, Nam et al. Outcomes of cementless-backed patellar components. 0000042563 00000 n 60 0 obj 0000018274 00000 n Personalized Care. Failure mechanisms of metal-backed patellar components 2019;34(2):309-314, American Joint Replacement Registry (AJRR): 2019 Annual Report. Biomaterials (2008), 1-13. Pohler, O EM. 0000030877 00000 n Williams, DF. 0000030284 00000 n Unique to this set is an adjustable parallel offset guide, a C-ring drill guide with an incorporated measurement device, and a cerclage wire passer to effectively pass wire through the quad and patellar tendons. Orlando, FL. Dr. Schiff shares his experiences with the VariAx 2 plating platform. The 2.7mm VA Locking Anterior Patella Plate is designed for utility across various fracture patterns. Arthrex, Inc. Data on file (Patella Fracture Study [Study #318]). Sagittal fractures are more easily reduced with the knee flexed. 99.5% all-cause survivorship in 1024 Triathlon PS cementless TKA at four-year follow-up.16Both Tritanium and PA beaded versions of the tibial baseplate and metal-backed patella were included. The patella component is the plastic or metal piece that is inserted into the patella, or kneecap. The 4.0 mm blunt-tipped cannulated screws were designed specifically for patella fractures. 0000044033 00000 n Henderson, CE et al. Orthopaedic Trauma | DePuy Synthes - J&J MedTech A low prole 2.3 mm titanium mesh plate (Stryker, Mahwah, NJ) was cut to t, and then it was xed to the anterior surface of the patella using non-locking 2.3 mm screws (Figure 7A). 2018, https://www.aaos.org/globalassets/quality-and-practice-resources/surgical-management-knee/smoak-cpg_4.22.2016.pdf, Memtsoudis et al. For plates, screws, bone void fillers, and DBM: C1713 - Implantable pins and/or screws that are used to oppose soft tissue-to-bone, tendon-to-bone, or bone-to-bone. Results of cemented vs cementless primary total knee arthroplasty using the same implant design. Poster presented at: Orthopaedic Research Society (ORS) 2020 Annual Meeting; February 8-11, 2020; Phoenix, AZ. If you choose to logout it will log you out from all the applications. 0000035804 00000 n The cannulated screws compress the fracture and the blunt tips prevent lacerations to the FiberTape. 0000048947 00000 n Silverstein et al. The patented polyaxial locking technology and low profile design were created using our SOMA database. Fit for patients Fit for procedures Fit for you Fit for the future Contact Related categories Instructions Precontoured plates are designed to act as a template by replicating scapular anatomy and may help save operating time by reducing the need for plate bending. Harwin et al. AxSOS 3 Ti Proximal Tibia | Stryker - Stryker Corporation EasyClip. Every minute counts in the OR. 3. iD Solutions - Individually Designed. The 2.7mm VA Locking Anterior Patella Plate is designed for utility across various fracture patterns. Wound healing should be assessed regularly during the first two weeks. Compared to traditional K-wires, this construct has been shown to be stronger.1. Perioperative and Early Postoperative Comparison of a Modern Cemented and Cementless Total Knee Arthroplasty of the Same Design. Trainings Orthobiologics Low patella complication and accurate patella tracking can be achieved with this product. Tibia and femur | Stryker Simplicity and adaptability with seven new indication specific plates using the comprehensive locking and non-locking screw system. The patello-femoral joint is biomechanically very stressed when the knee is loaded. Monoaxial locking plate system for treating proximal tibia fractures. It is, therefore, highly desirable, in patellar fractures to strive for anatomical reduction of the joint surface and stable fixation. If you choose to logout it will log you out from all the applications. The Patella Fracture System includes everything needed to repair transverse patella fractures. This procedure is normally performed with the patient in a supine position with the knee flexed 30. Early progressive, active mobilization is beneficial after surgery. Solving complicated fractures with simple innovative solutions - Plating that fits. 0000007480 00000 n 5 year follow up data for cementless total knee arthroplasty patients. In addition, FiberTape suture has been attached to 5 in needles designed to pass through the screws, subsequently allowing for its use as a tension band. This construct has been shown to be stronger than the traditional K-wire with cerclage wire constructs.1. The precontoured plate is designed to match the patient's own scapula curvatures and help restore the original anatomy. 0000044805 00000 n Abdel et al. Osteoarthritis and Cartilage 2015; 23: 1664e1673, Johnson et al. This clinical picture is in the middle of the operating procedure. Arthrex - Patella Fracture 2018 World Arthroplasty Congress. Only by truly understanding the challenges you face can we offer a portfolio to best fit your needs. We use cookies to customize content for your viewing and for analytics. Our plating portfolio ranges from indication specific plates and patented Smartlock technology to streamlined instrumentation for ease-of-use in the OR. 0000008580 00000 n The mesh plates, which are offered in short and long lengths, can be cut and contoured to the desired size and shape based on fracture patterns. The 4.0 mm blunt-tipped cannulated screws were designed specifically for patella fractures. Rome, Italy. Universal Neuro III. Patella SuturePlate II To address various types of fractures, the Patella SuturePlate II system offers three types of plates in different sizes. View and Download Stryker Triathlon Knee System surgical protocol online. The 4.0 mm blunt-tipped cannulated screws were designed specifically for patella fractures. It covers the incision, the desired outcome, the osteotomy and fixation. The Patella Fracture System includes everything needed to repair transverse patella fractures. 2. Clinical performance of a novel 3D printed cementless titanium tibial baseplate, 2-4 year follow-up. J Arthroplasty 2015;30:2181e4. Orthopaedic Research Society 2020 Annual Meeting. 0000016026 00000 n Consideration should be given to thrombo-embolic prophylaxis, according to local treatment guidelines. FiberTape, 2 mm with Braided Polyblend Suture Blue with Straight Needle, Low Profile Screw, Cannulated, Blunt Tip, 4 x 24 mm, Low Profile Screw, Cannulated, Blunt Tip, 4 x 26 mm, Low Profile Screw, Cannulated, Blunt Tip, 4 x 28 mm, Low Profile Screw, Cannulated, Blunt Tip, 4 x 30 mm, Low Profile Screw, Cannulated, Blunt Tip, 4 x 32 mm, Low Profile Screw, Cannulated, Blunt Tip, 4 x 34 mm, Low Profile Screw, Cannulated, Blunt Tip, 4 x 36 mm, Low Profile Screw, Cannulated, Blunt Tip, 4 x 38 mm, Low Profile Screw, Cannulated, Blunt Tip, 4 x 40 mm, Low Profile Screw, Cannulated, Blunt Tip, 4 x 42 mm, Low Profile Screw, Cannulated, Blunt Tip, 4 x 44 mm, Low Profile Screw, Cannulated, Blunt Tip, 4 x 46 mm, Low Profile Screw, Cannulated, Blunt Tip, 4 x 48 mm, Low Profile Screw, Cannulated, Blunt Tip, 4 x 50 mm, Low Profile Screw, Cannulated, Blunt Tip, 4 x 55 mm, Low Profile Screw, Cannulated, Blunt Tip, 4 x 60 mm, Surgical Technique Videos | 07:26 | English | 07/05/2016 | VID1-00635-EN B, Surgical Technique Videos | 09:57 | English | 04/04/2022 | VID1-002599-en-US A, Surgical Technique Animations | 01:54 | English | 03/19/2020 | AN1-00144-EN D, Surgical Technique Guides | English | 06/16/2016 | LT1-00012-EN B, 09:57 | English | 04/04/2022 | VID1-002599-en-US A, 04:22 | English | 02/04/2022 | VID1-003070-en-US A, 06:28 | English | 01/06/2020 | VID1-000674-en-US A, 13:59 | English | 06/04/2018 | VID1-01280-EN A, 07:26 | English | 07/05/2016 | VID1-00635-EN B, 02:13 | English | 01/13/2023 | AN1-000279-en-US B, 02:32 | English | 06/10/2021 | AN1-000273-en-US A, 01:54 | English | 03/19/2020 | AN1-00144-EN D, English | 03/03/2023 | LT1-000206-en-US B, English | 11/25/2020 | LT1-000190-en-US A, 01:08 | English | 09/20/2018 | PAN1-00144-EN D, 09:28 | English | 05/19/2020 | VID1-000948-en-US A, 15:52 | English | 05/25/2018 | VPT1-01042-EN A, 01:20 | English | 11/10/2017 | VID1-00639-EN C, 08:25 | English | 10/23/2017 | VPT1-00849-EN A, English | 04/12/2019 | DOC1-000054-en-US A.